<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-15 11-12-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 76 dBuV NOSTALGI
Pilot RDS Phase Difference
6.0 kHz 3.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 69 kHz 19060 0,0105
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 5,83 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Queen - Love of my life "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 69 kHz MIN: 8 kHz % above 76 kHz: 0,0105 Acquired: 2024/12/15 11.11.20 Total samples: 19060 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 4,6 dBr AVE: 5,83 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2024/12/15 11.11.20) 10.58 11.00 11.02 11.04 11.06 11.08 11.10 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]